Abstract

In this study, the influence of slot opening on the leakage reactance, power factors, winding current, and air gap flux density, as well as other parameters of the surface-mounted permanent magnet synchronous motor driven by an inverter is analyzed using the two-dimensional time-step finite element method. Thus, the law of permanent magnet power loss caused by slot opening under PWM qa obtained. The results show that the leakage reactance of the motor increased when the slot opening decreased from 7 mm to 2 mm. Then, the armature ripple current caused by the inverter was found to be suppressed well, and the high harmonic current was filtered well. This reduced the amplitude of the high-order harmonic of the air gap flux density, and the permanent magnet power loss was reduced by nearly 75%. Finally, two prototypes with different slot openings were tested for permanent magnet temperature rise, which verified the analysis method and calculation results proven in this paper.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.