Abstract
In clinical practice, stent diameter is one of the variable properties important for endovascular treatment. A consensus guideline for stent retriever size selection has yet to be established. The aim of this study was to investigate the effects of different diameters of Solitaire retrievers on outcomes. Of 628 patients enrolled from the Endovascular Treatment for Acute Anterior Circulation Ischemic Stroke Registry, 256 were treated with the Solitaire 4-mm device and 372, with the 6-mm device. We matched patients treated with the 2 stent sizes using propensity score analysis. The successful outcome was reperfusion as measured by the modified Thrombolysis in Cerebral Infarction score immediately postprocedure and the dichotomized modified Rankin Scale score at 90 days. Symptomatic intracerebral hemorrhage and in-hospital mortality were also recorded. After propensity score analysis, group outcomes did not differ. In addition, in patients with atherosclerosis-related occlusion, a higher reperfusion rate (P = .021) was observed in the Solitaire 4 group, as well as a shorter time interval (P = .002) and fewer passes (P = .025). Independent predictors of successful reperfusion in patients with atherosclerotic disease on logistic analysis were the small stent (OR, 3.217; 95% CI, 1.129-9.162; P = .029) and the propensity score acting as a covariate (OR, 52.84; 95% CI, 3.468-805.018; P = .004). We found no evidence of a differential effect of intra-arterial therapy based on the size of Solitaire retrievers. In patients with atherosclerotic disease, favorable reperfusion was associated with deployment of a small stent.
Highlights
BACKGROUND AND PURPOSEIn clinical practice, stent diameter is one of the variable properties important for endovascular treatment
Independent predictors of successful reperfusion in patients with atherosclerotic disease on logistic analysis were the small stent (OR, 3.217; 95% CI, 1.129 –9.162; P ϭ .029) and the propensity score acting as a covariate (OR, 52.84; 95% CI, 3.468 – 805.018; P ϭ .004)
We found no evidence of a differential effect of intra-arterial therapy based on the size of Solitaire retrievers
Summary
The aim of this study was to investigate the effects of different diameters of Solitaire retrievers on outcomes. We aimed to evaluate the impact of the sizes of stentlike thrombectomy devices on the outcome of treated patients with ischemic stroke due to large-vessel occlusion of the anterior circulation
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.