Abstract
In order to examine the effect of radiation power loss due to impurity gas puff in divertor plasma, we calculated time evolution of impurity ion densities and electron temperature for several cases with Ne gas puff rates 1012 and 1013 cm−3 s−1 during 0.01 s and initial electron temperature 10-300 eV for a plasma with electron density 1013 cm−3 with a one zone model. We found that the electron temperature decreases less than 1 eV for the cases with gas puff rate 1013 cm−3 s−1, independent of initial electron temperature and in this case we expect plasma detachment. Detailed conditions for plasma detachment should also depend on time history of radiation power.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.