Abstract
The effect of applied potential on the stress corrosion cracking (SCC) initiation of X-70 pipeline steel in near-neutral pH solution has been investigated by using a slow strain rate testing (SSRT) apparatus and electric potential drop (EPD) method. It was found from the SSRT results that the initiation stress decreased with the decrease in the potential from -790mVSCE to -950mVSCE. But the initiation stress increased when the applied potential was at -1100mVSCE and then decreased at -1200mVSCE. The initiation stress also decreased when the anodic potentials were applied to the samples. SEM observations favored the above SSRT results.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.