Abstract

Measurements of the drop size distributions were obtained for air and water flowing in an annular pattern in a 2.54 cm horizontal pipe. A laser diffraction technique was used. The data were obtained at the centerline. These are compared with measurements obtained previously for annular flow of air and water in a horizontal 9.53 cm pipe in the same flow loop and with the same instrumentation. The volume median drop diameter for these two flows was found to increase with pipe diameter and to vary with D 0.5 for superficial gas velocities larger than 30 m/s.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.