Abstract
Peri-implantitis is caused by biofilm adhering to the implant. It has been shown that bactericidal electrolysis products are generated when a low direct current is applied to a titanium implant used as the anode. The hypothesis of this study was that low-current electrolysis would eradicate viable bacteria in a simulated subgingival multispecies biofilm adhering to a titanium implant surface. Biofilms consisting of eight anaerobic species were grown on pellicle-coated titanium discs with sand-blasted, acid-etched, large-grit (SLA; Straumann, Basel, Switzerland) surface. After 40.5 hours of growth, discs were treated with 10 mA for 10 minutes in an electrolytical setup with physiological saline and gelatin. Low direct current at discs used as the cathode caused a reduction of three to four orders of magnitude in viable counts, while no viable bacteria were recovered from anode discs (Mann-Whitney U-test, p < .01). Confocal laser scanning microscopy in combination with a live/dead stain showed biofilm detachment at the cathode and reduced viability at the anode. Electrochemical treatment of diseased implants appears to be promising and well worth investigating further.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.