Background: Alignment of the teeth as the first stage of comprehensive orthodontic treatment has widely been addressed. Several methods such as using super elastic arch wires, multi-strand wires and incorporation of various loops into the round stainless steel wires have been suggested in this stage. Objectives: The aim of this study was to investigate and compare the horizontal forces produced by six various loop designs in different amounts of activation using the finite element method. Materials and Methods:The Finite Element Model (FEM) was used to design and compare the horizontal forces of round 0.014 inches stainless steel vertical open loop, vertical closed loop, vertical helical open loop, vertical helical closed loop, plain vertical loop and the squash loop. The forces were measured at 0.1, 0.4, 0.8 and 1mm activations. Results: For all activations, vertical open loop had the highest horizontal force; while vertical helical closed loop showed the lowest force. Conclusions: The design of vertical loops influences the horizontal force in all activations, immensely.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.