Abstract
A study was conducted to identify the optimal temperature and time at which heat treatment of bovine colostrum would least change viscosity and IgG concentrations yet reduce bacterial count. First-milking colostrum with >50g of immunoglobulins/L (measured by colostrometer) was collected from 30 Holstein cows. Aliquots of colostrum were heated for 0, 30, 60, or 90min at 57, 60, or 63°C in a water bath. Samples were examined for viscosity, IgG1, and IgG2 concentrations, standard plate count, coagulase-negative staphylococci, environmental streptococci, coliform, gram-negative noncoliform, Streptococcus agalactiae, and Staphylococcus aureus counts. All heat treatments reduced counts of all bacteria groups measured compared with untreated colostrum samples. Heat treatment at ≥60°C denatured IgG1 compared with untreated colostrum; however, colostral IgG2 levels were not reduced when temperature was held at 60°C for <60min. Viscosity was not affected when temperature was held at 60°C for <60min. In this study, heat treatment of bovine colostrum at 60°C for 30 or 60min reduced bacterial count, slightly reduced IgG concentration, and did not affect viscosity.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.