Abstract
In this paper, a rotor test device for vertical-horizontal conversion is designed. The effects of unbalanced mass, dynamic balance position and other dynamic balance parameters on the vibration response of the rotor system are experimentally analyzed, and the difference of the vibration response of the rotor system between vertical and horizontal States is compared. The test results show that the vibration of the bearing base foot will increase after the dynamic balancing rotor is installed in the vertical shafting in the horizontal state; in order to ensure the dynamic balancing accuracy, the dynamic balancing of the vertical rotor system should be carried out on the vertical system as far as possible, and the aggravation should be carried out far away from the driving end. The research results in this paper can provide necessary support for the determination of dynamic balancing process and the study of dynamic characteristics of vertical rotors.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: IOP Conference Series: Materials Science and Engineering
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.