Abstract
An experimental investigation has been conducted on critical heat flux (CHF) on a horizontal tube in crossflow boiling R-113 at near atmospheric pressures. Data were obtained over a range of fluid velocities (up to 0.52 m/s), heater diameters (8 to 12.7 mm), and flow blockage factors (D/H = 0.31 to 0.5). The effect of the flow blockage on CHF was examined in detail and compared with other data and existing correlations. No significant effect of flow blockage was observed for D/H up to 0.5. An analytical modification of the Katto-Haramura CHF correlation is proposed to take into account the effect of flow blockage over a wide range of D/H.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.