Abstract

This study was conducted to experimentally investigate the shear behavior of non-ductile squat shear walls with different cement matrixes such as normal concrete, fiber-reinforced concrete(FRC), and strain-hardening cement composite(SHCC). The cement matrix type’s effect in the lightly reinforced squat shear wall was evaluated through the testing of three one-third scale walls with a height-to-length ratio (hw/lw) of 0.55 under top displacement reversals. Experimental results show that the cement matrix type in the non-seismically detailed squat shear walls has a significant effect on the shear behavior and failure mode. Compared to reinforced FRC and SHCC shear walls, reinforced concrete wall exhibited brittle behavior. Reinforcing fibers in the FRC and SHCC mitigated the crack damage of wall and increase the shear strength.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.