Abstract

Experimental data on dividing steam-water two-phase annular flow in T-junctions with horizontal inlet and downwardly inclined branches were obtained. The experiments were performed under experimental conditions which have not been examined before. The branch orientation was found to be a significant parameter affecting phase redistribution in the junction. Increasing the downward inclination of the branch was found to reduce the degree of phase separation in the junction under the present test conditions. This is caused by the nonuniform distribution of the liquid film thickness associated with the horizontal inlet annular flow. The phase redistribution data were compared with available models. The need for additional modelling studies was evident. The pressure changes of two-phase flow in the junction were closely correlated with the phase redistribution phenomenon. The data on pressure changes in the junction were correlated using simple models based on momentum and mechanical energy balances.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.