Abstract

Anodic oxidation is an electrochemical method to deposit ceramic coatings on the metals substrate to improve the bioactivity. This study aims to investigate the effect of bath temperature on the surface properties of anodised titanium. High-purity titanium foil was modified by anodising in mixture of β-glycerophosphate disodium salt pentahydrate (β-GP) and calcium acetate monohydrate (CA). The experiments were carried out at 350 V, 30 mA.cm-2 for 10 minutes at different bath temperature (4-100 °C). Field emission scanning electron microscopy (FESEM), glancing angle X-ray diffractometer (GAXRD) and goniometer were used to characterise the surface morphology, mineralogy and wettability of anodised titanium, respectively. The results showed that porosity and crystallinity of surface decreased as increasing of bath temperature. Interestedly, the α-tricalcium phosphate (α-TCP) was deposited on the samples which anodisation at higher bath temperature (≥ 60 °C) and resulted high hydrophilicity behaviour even the surface was found relatively smooth.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.