Abstract
Convective heat transfer coefficient between absorber plate and air in a flat-plate solar air heater can be enhanced by providing the absorber plate with artificial roughness. An investigation of fully developed turbulent flow in a solar air heater duct with small diameter protrusion wires on the absorber plate has been carried out and expressions for prediction of average Stanton number and average friction factor have been developed. The results of these expressions have been compared with available data. The results have been found to compare with a mean deviation of 6.3% for friction factor and −10.7% for the Nusselt number. The effect of height and pitch of the roughness elements on the heat transfer rate and friction has also been investigated.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.