Abstract

We have recently shown that valve sparing reimplantation (VSR) improves the durability of bicuspid aortic valve repair in comparison with subcommissural annuloplasty. The aim of this study was to assess the degree of annular reduction provided by these techniques and to correlate these findings with repair durability. From 1995 to 2010, 161 patients underwent bicuspid valve repair. We included only patients with subcommissural annuloplasty or reimplantation having intraoperative pre- and post-repair transoesophageal echocardiography images. Pre- and post-repair ventriculo-aortic junction (VAJ) diameters were measured on long axis views. Inclusion criteria were met by 53 patients with subcommissual annuloplasty and 65 with reimplantation. Median follow-up was 53 months in the subcommissual annuloplasty group and 42 months in the reimplantation group. Follow-up completeness was 100% in subcommissural annuloplasty and 94% in reimplantation. There was no operative or late mortality. Mean preoperative VAJ was similar in both groups (reimplantation: 28 ± 3 mm vs subcommissural annuloplasty: 28 ± 3, P = 0.16). Preoperative VAJ was larger in patients <40 years and with aortic regurgitation (AR) ≥ 3+ (P < 0.01). Mean postoperative VAJ was smaller in reimplantation compared with subcommissural annuloplasty (21 ± 2 mm vs 24 ± 3 mm, P < 0.01). In univariate analyses, subcommissural annuloplasty, preoperative VAJ ≥ 30 mm, postoperative VAJ ≥ 25 mm and cusp repair with patch were predictive of recurrent AR > 1+. In the subcommissural annuloplasty group, VAJ≥ 30 mm preoperatively and ≥ 25 mm postoperatively were associated with decreased 6 years freedom from recurrent AR>1+ (<30 mm: 74% vs ≥ 30 mm: 39%, P = 0.01; <25 mm: 80% vs ≥ 25 mm 31%, P = 0.02) In the reimplantation group, VAJ dimension had no effect on recurrent AR >1+ (P = 0.93). In bicuspid aortic valve repair, the circumferential annuloplasty of VSR offers greater reduction of VAJ compared with the non-circumferential annuloplasty provided by the subcommissural annuloplasty. The degree and extent of VAJ reduction in reimplantation seem to be factors among others that positively influence repair durability particularly in patients with a large VAJ (≥ 30 mm).

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.