Abstract
The pulse-height distributions from known amounts of 222Rn and its daughters were measured as a function of the volume of the scintillator solution and compared with the air luminescence spectrum from α-particles in air. The results indicate that 222Rn and its daughters in the gaseous space above the liquid scintillator produce the air luminescence counts which lead to errors in quantitative determination of 222Rn by liquid scintillation counting unless necessary corrections for the counts are made. The error inherent in the conventional determination of 222Rn by liquid scintillation counting is evaluated. Methods for correcting the air luminescence counts are discussed.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: International Journal of Radiation Applications and Instrumentation. Part A. Applied Radiation and Isotopes
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.