Abstract
Using orthogonal experimental design method structure parameters of work piece for muffler element with inserted tube are determined. Flow noise regeneration of them is measured on the self development test bench. Relationship model on total sound power of flow regeneration noise and structure parameter and flow velocity is established utilizing Multiple linear regression method, model parameters are solved making use of hyper static least square method. Significance test of the model is performed, the law of total sound power level for muffler element flow regeneration noise changing with the parameters is discussed. Result shows that the established models is all highly significant under 0.01 levels, and inserted length of outlet tube and inn-diameter of inlet tube have higher effect on the flow generation noise, and decreasing the inserted length and the inn-diameter are in favor of reducing flow generation noise. But inserted length of inlet tube and expansion ratio have little effect on the flow generation noise.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.