Abstract

EDTA is the most widely used chelating agent for removal of undesirable cations in many industrial applications such as the dairy industry. It is generally considered to be non-biodegradable by conventional wastewater treatment, thereby potentially producing an environmental health risk. Under suitable conditions, however, EDTA has been reported to be effectively degraded by micro organisms during wastewater treatment. This study examined degradation of EDTA from a dairy wastewater treatment process in New Zealand operated at pH 8.0-8.2, with a three-week sludge retention time. An HPLC-UV analytical method was used to measure EDTA. A wide range of EDTA concentrations (93 to 5194 µg/L) was measured in the influent entering the wastewater treatment plant, while concentrations of 72–260 µg/L were measured in dairy effluent discharged into the local stream. About 93% of EDTA was degraded by the wastewater treatment. This study demonstrates that the wastewater treatment process at a dairy plant in New Zealand was very effective in removing EDTA.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.