Abstract

The operation of a PIUS-type reactor requires controlling the reactor pump speed to keep stationary the hot/cold liquid interfaces between the reactor coolant and cold borated water. The dynamic response of the interface location to pump speed perturbations is analyzed for an experimental loop simulating a PIUS-type reactor. The transfer function between the pump speed and the interface location is obtained by perturbing and Laplace-transforming the one-dimensional fluid momentum equations. The analytical results agree well with experimental data taken from the same facility. It is shown that the magnitude of the phase lag in the response of the interface location, which needs to be considered in designing a pump speed controller, primarily depends on the fluid inertia in the loop, the density lock flow area, and the density difference between the simulated reactor coolant and borated water.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.