Abstract

Renal hypoxia may play an important role in the progression of diabetic nephropathy. However, tools that noninvasively and quantitatively measure oxygen tension in the kidney are lacking. Here, we evaluated the feasibility of a noninvasive and quantitative imaging technique using dynamic nuclear polarization magnetic resonance imaging (DNP-MRI) in combination with the oxygen-sensitive paramagnetic agent OX63 for measuring oxygen tension in the kidney. Our results demonstrate that the DNP-MRI technique can yield quantitative maps of oxygen tension in the mouse renal cortex. Using this procedure, we also showed that oxygen tension was less elevated in the renal cortex of both streptozotocin-induced type 1 diabetic mice and db/db mice, a model of type 2 diabetes, than in the renal cortex of age-matched control mice of each respective model. Oxygen tension in streptozotocin-exposed mice was significantly improved by insulin treatment. Thus, the noninvasive and quantitative DNP-MRI technique appears to be useful for studying the pathophysiological role of hypoxia.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.