Abstract

A new parallel plate capacitance sensor was built consisting of two metal sheets. The sensor – a capacitor and the whole oscillating circuit was driven at 27 MHz frequency. Dynamic laboratory experiments were performed with grass from a natural meadow in order to evaluate the possibility of the forage mass flow determination by means of this sensor. The results revealed a relatively strong linear relationship between the feed rates of the wet forage crop material passing through the sensor between its plates and the measured capacitance sensor circuit output frequency. The coefficients of determination (R<sup>2</sup>) varied from 0.9 to 0.96. Further improvement of the electronic circuit connection and further investigation of the sensor can be recommended.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.