Abstract

In this paper, instrumented tension-impact (dynamic tensile) and instrumented Charpy impact test results for AISI 308 stainless steel welds at room temperature are reported. A few Charpy specimens precracked to a/W (crack length to width ratio) ratios of 0.42 to 0.59 were also tested. Dynamic yield strength obtained from tension-impact test agrees well with that from Charpy V-notch specimens. The strain rates obtained during the tension-impact test are compared with the various estimates of strain rates for V-notch and precracked Charpy specimens. A variation of the compliance changing rate method was necessary for determining the crack initiation point while crack growth was determined by power law key-curve procedure. J-R curves thus obtained from Charpy (precracked and V-notch) specimens are compared with those computed using handbook procedures using dynamic tensile results.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.