Prefabricated panels are handled by various types of crane during the assembly (bridge crane in the production hall and construction crane on site). The panel is loaded with inertial forces during manipulation caused by crane's starting and breaking movement. These forces significantly affect the design of the transport system (anchors, ropes, etc. In literature there are different values of dynamic coefficient for different types of crane. In the experiment, the magnitude of the force in the crane hinge was measured during the handling of various panel types in the production hall and during the construction site installation. The static value of the force size was determined at the moment when the panel freely hanged on crane hinge. The measured values are further compared with the manufacturer’s recommendation for the design of the transport anchors.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.