Abstract

We present a new OCT technique which renders the transversal resolution depth independent. This is achieved by an optical setup which shifts the focus of the beam illuminating the object through the object depth without changing the path length in the corresponding interferometer arm. Therefore, the coherence gate remains at the beam focus without any readjustment of the reference arm. Depth resolution was tested with the help of microscopy cover-plates and transversal resolution was tested with the help of Ronchi rulings. Resolution was 100 lines mm−1 over an object depth of 430 μm. For a first demonstration of the properties of this dynamic coherent focus scheme in a biologic system a section of a human cornea was used. We expect that this technique can further be improved to obtain transversal resolution down to the 1-μm range

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.