Abstract
BackgroundPrevious studies have indicated that oxygen uptake (VO_2) is one of the most accurate indices for assessing the cardiorespiratory response to exercise. In most existing studies, the response of VO_2 is often roughly modelled as a first-order system due to the inadequate stimulation and low signal to noise ratio. To overcome this difficulty, this paper proposes a novel nonparametric kernel-based method for the dynamic modelling of VO_2 response to provide a more robust estimation.MethodsTwenty healthy non-athlete participants conducted treadmill exercises with monotonous stimulation (e.g., single step function as input). During the exercise, VO_2 was measured and recorded by a popular portable gas analyser (K4b^2, COSMED). Based on the recorded data, a kernel-based estimation method was proposed to perform the nonparametric modelling of VO_2. For the proposed method, a properly selected kernel can represent the prior modelling information to reduce the dependence of comprehensive stimulations. Furthermore, due to the special elastic net formed by mathcal {L}_1 norm and kernelised mathcal {L}_2 norm, the estimations are smooth and concise. Additionally, the finite impulse response based nonparametric model which estimated by the proposed method can optimally select the order and fit better in terms of goodness-of-fit comparing to classical methods.ResultsSeveral kernels were introduced for the kernel-based VO_2 modelling method. The results clearly indicated that the stable spline (SS) kernel has the best performance for VO_2 modelling. Particularly, based on the experimental data from 20 participants, the estimated response from the proposed method with SS kernel was significantly better than the results from the benchmark method [i.e., prediction error method (PEM)] (76.0pm 5.72 vs 71.4pm 7.24%).ConclusionsThe proposed nonparametric modelling method is an effective method for the estimation of the impulse response of VO2—Speed system. Furthermore, the identified average nonparametric model method can dynamically predict VO_2 response with acceptable accuracy during treadmill exercise.
Highlights
Previous studies have indicated that oxygen uptake (V O2 ) is one of the most accurate indices for assessing the cardiorespiratory response to exercise
We showed through several simulation examples that stable spline (SS) and DC kernels can achieve higher accuracy compared to diagonal kernel (DI) kernel for this problem
In order to obtain a better finite impulse response (FIR) model of the oxygen uptake model, we introduce a newly developed kernel method based on the work in [14, 15]
Summary
Previous studies have indicated that oxygen uptake (V O2 ) is one of the most accurate indices for assessing the cardiorespiratory response to exercise. The response of VO2 is often roughly modelled as a first-order system due to the inadequate stimulation and low signal to noise ratio To overcome this difficulty, this paper proposes a novel nonparametric kernel-based method for the dynamic modelling of VO2 response to provide a more robust estimation. The work in [12] has developed a nonlinear dynamic model for oxygen uptake modelling during treadmill exercise with pseudo random binary signal (PRBS) as the input. It is relatively difficult for the exercisers to follow the PRBS signal during the treadmill exercise generally
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.