Abstract
In this paper we present the most significant testbeam results of a dual-readout fibre calorimeter module equipped with silicon photomultipliers (SiPMs) to sense the scintillation and Cherenkov light signals. The main challenges of this detector are the minimization of the optical crosstalk between the two signals and the potential saturation of the digital SiPM-based readout. Both topics have been investigated with encouraging results. As a by-product of this extremely granular readout, the lateral profile of electromagnetic showers was sampled with an unprecedented precision close to the shower axis and significant differences were observed between the scintillating and Cherenkov signals.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.