Abstract

Rheumatoid arthritis can manifest itself through synovitis, of which the knee is the common locale. The treatment using an intra-articular radioisotope injection has been applied in various countries. In this work, the dose of radioactive material absorbed in the joint is evaluated, taking into consideration the dose received in the articular cartilage and adjacencies using a three-dimensional voxel model representing the knee. The radioisotopes studied were Samarium-153 and Dysprosium-165. The results show that the synovial membrane receives 85 to 98% of the normalized dose taken from all voxels representative of the synovium. The following features of 153Sm and of 165Dy - its short physical half-life, the gamma emissions with low energy which allow monitoring the injection trough scintigraphy images, the possibility of binding themselves to macroaggregates that are retained in the joint, the high percentage of the effective dose spread in the synovial membrane - make these suitable radioisotopes for radiation synovectomy.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.