Abstract

The particle beam, during injection into the storage ring, can be partly lost in one of the transition regions between the storage-ring vacuum chamber and the insertion-device (ID) straight section. The transition region is a copper interface between a standard aluminum vacuum chamber and an insertion-device vacuum chamber. This can be a problem, at least in the first few insertion devices where the injected beam is still unstable. It may create higher photon and neutron dose rates in the first optical enclosures of the upstream ID beamlines adjacent to this region. This report presents the results of the dose rate estimates for such an event and some recommendations for mitigation.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.