Abstract

Irradiation of humans with negative pions requires a knowledge of the absorbed dose and radiation quality outside the primary pion beam. In conjunction with early clinical trials at LAMPF, experimental data have been obtained with microdosimetric techniques and multiwire proportional counters. Theoretical calculations have been made for the neutron contribution to the dose and are consistent with these data. Measurements were made within a 40 cm*51 cm*76 cm water phantom for a negative pion beam of initial momentum of 170 MeV/c, Delta p=+or-3 MeV/c. The absorbed dose outside the treatment volume is the result of: (1) neutrons and photons from the pion interactions, (2) treatment room background and (3) peripheral muons, electrons and pions in the primary beam.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.