Abstract

One of the essential parameters influencing of the dose conversion factor is the ratio of unattached short-lived radon progeny. This may differ from the value identified for indoor conditions when considering special workplaces such as mines. Inevitably, application of the dose conversion factors used in surface workplaces considerably reduces the reliability of dose estimation in the case of mines. This paper surveyed the concentration of radon and its short-lived radon progeny and identified the unattached fraction of short-lived radon progeny. As well equilibrium factor during the month of August was calculated simultaneously at two extraction faces in a manganese ore mine. During working hours the average radon concentrations were 220 Bq m −3 and 530 Bq m −3 at Faces 1 and 2; the average short-lived progeny concentration was 90 Bq m −3 and 190 Bq m −3, the average equilibrium factors were 0.46 and 0.36, and the average unattached fractions were 0.21 and 0.17, respectively. The calculated dose conversion factor was between 9 and 27 mSv WLM −1, but higher values could also be possible.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.