Abstract

This study investigates the impact of the anatomical separation point of the dorsal ulnar cutaneous nerve (DUCN) on nerve conduction studies (NCS). Involving 25 subjects with DUCN NCS findings, it utilizes ultrasound to mark the DUCN's divergence from the ulnar nerve. NCS was performed at four points relative to the separation point. The findings indicate the maximal amplitudes occurred 2 cm distal to the separation point. The study suggests it is ideal when the stimulation is performed between the seperation point and 2 cm distal to it.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.