Abstract
To define a protocol for surrogate measurement of magnetic field exposure by questionnaire, a series of spot and 24-hour measurements was made at 50 houses in Avon, UK. Measurements were made with Emdex ll equipment in the centres of rooms with the house power encountered at the start of the visit, and then with all power to the house isolated at the main switch. The mean spot magnetic field averaged over the 50 homes for each room varied between 0.011 and 0.023 T with an overall mean (0.0170.003) T with the power `on', and between 0.008 and 0.015 T, giving an overall mean (0.0120.002) T with power `off'. Measurements over 24 h in the three main occupancy rooms showed a distinct diurnal variation in the overall mean magnetic field of the 50 homes by a factor of three, giving a 24-hour mean of (0.0440.06) T; at the same time mean recorded personal exposure for the occupants monitored was (0.0670.08) T. These values appear low compared with, for example, USA domestic levels of magnetic field exposure demonstrated in several studies, but also show a wide variation in individual values, which could not be predicted from spot measurements.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.