Abstract

The article deals with the analysis of the problem of the load-bearing capacity of reinforcing bars placed above the columns in slab-column connections of reinforced concrete structures. Failure of the support zone by punching and lack of proper structural integrity reinforcement can lead to a progressive collapse. The EC2 standard guidelines recommend the use of integrity reinforcement, however, they lack any instructions concerning the amount of necessary reinforcement. The article presents a theoretical calculation model that permits a more detailed analysis of internal forces in reinforcing bars located directly above the column. Adopting a solution in the form of exact equations makes it possible to take into account the influence of a non-linear change of the bar stiffness and considerable deflections. The calculation model is based on the results of experimental investigations. On the basis of a theoretical model it is possible to estimate the tensile force of the bar at which the bars located directly in the support zone are ruptured.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.