Abstract
In order to improve the dynamic performance, based on the analysis of the dynamic model of doubly fed induction generator (DFIG), this paper presents an improved direct power control strategy which is based on the direct control of stator active and reactive power of DFIG. The proposed method only utilizes the estimated stator flux by the stator resistance which is the only machine parameter, so as to remove the power dithering resulting from the inaccuracy associated with rotor flux estimation. In the Matlab/Simulink, simulation results for a 15KW DFIG system demonstrate the high accuracy and excellent dynamic performance during variations of active and reactive power, and revolution.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.