Abstract

BackgroundIt is unknown, whether cardiac troponin (cTn) I or cTnT is the preferred biomarker in the detection of exercise-induced myocardial ischemia. MethodsWe investigated patients with suspected myocardial ischemia referred for exercise or pharmacological rest/stress myocardial perfusion single-photon emission computed tomography (SPECT) to directly compare the diagnostic accuracy of high-sensitivity cTnI (hs-cTnI) and hs-cTnT. Diagnostic performance was analyzed separately according to stress modality. Hs-cTnI and hs-cTnT were measured before, immediately after, as well as 2h and 4h after maximal exercise in a blinded fashion. Further, all clinical information available to the treating cardiologist was used to quantify the clinical judgment regarding the presence of myocardial ischemia using a visual analog scale twice: once prior and once after stress-testing. The presence of stress-induced myocardial ischemia was adjudicated using SPECT combined with coronary angiography findings. ResultA total of 403 consecutive patients were enrolled in our study, of which 229 underwent exercise stress and 174 patients pharmacological stress. Exercise-stress-induced myocardial ischemia was detected in 90 patients (39.3% of 229). Levels of hs-cTnI and hs-cTnT were both significantly higher at all time-points examined in patients with exercise-induced myocardial ischemia as compared to patients without myocardial ischemia (all p<0.001). Correlation of hs-cTnI and hs-cTnT was high in direct comparison of time-points (Spearman's rho all ≥0.7). The AUCs for baseline/peak/2h/4h for hs-cTnI and hs-cTnT were 0.71/0.71/0.72/0.69 vs. 0.74/0.73/0.71/0.72, respectively (all p=ns for hs-cTnI versus hs-cTnT). In patients undergoing pharmacological stress, the AUCs for baseline/peak/2h/4h for hs-cTnI and hs-cTnT were 0.66/0.66/0.68/0.67 and 0.61/0.62/0.64/0.59, respectively (all p=ns for hs-cTnI versus hs-cTnT). Also the combinations including clinical judgment or changes during serial sampling were similar for hs-cTnI and hs-cTnT (all p=ns). ConclusionsHs-cTnI and hs-cTnT provide comparable diagnostic information regarding exercise-induced myocardial ischemia. Overall, their diagnostic accuracy seems moderate. Unique identifierNCT01838148

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.