Abstract
ABSTRACT Context The elastomeric impression material is the most widely used impression material in contemporary dental practice; their accuracy is critical for the outcome of indirect restorations. The accurate duplicate cast obtained from single impression reduces the professional clinical time, patient inconvenience, and extra material cost. Aim To compare the accuracy of the cast obtained from various impression methods utilizing elastomer impression materials. Materials and methods The stainless steel working cast model assembly consisting of two abutments and one pontic area was fabricated. Two sets of six each custom aluminum trays were fabricated, with 5 mm spacer and 2 mm space. The impression methods evaluated in the study were additional silicone putty reline (two step), heavy-light body (one step), monophase (one step), and polyether (one step). Type IV gypsum casts were poured at intervals of 1, 12, 24, and 48 hours. The resultant cast was measured with a traveling microscope for comparative dimensional accuracy. The data obtained were subjected to analysis of variance test at significance level <0.05. Results The die obtained from putty reline two-step impression techniques had the percentage of variation for the height -0.36 to -0.97% with 0.40 to 0.90% increase in diameter. One-step heavy-light body impression dies recorded the increased width by 0.50 to 0.80% and height reduced by - 0.73 to -1.21%. The resultant dies from additional silicone monophase impressions had a percentage of variation for width 1.20% and height by-1.34%. The similar value for width and height for polyether was -1.46% and -1.30% respectively. Conclusion Putty reline technique dies had better dimensional accuracy after repeated pour followed by dies from heavy-light body additional silicone impression. Key message The multiple pour cast from putty reline elastomeric impressions is clinically acceptable, while cast from polyether was smaller in dimension. How to cite this article Haralur SB, Toman MS, Al-Shahrani AA, Al-Qarni AA. Dimensional Accuracy of Multiple Pour Cast from Different Elastomer Impression Techniques. Int J Prosthodont Restor Dent 2016;6(3):51-56.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: International Journal of Prosthodontics and Restorative Dentistry
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.