Abstract

A digoxin-like immunoreactive substance (DLIS) has been reported in the amniotic fluid. Since radioimmunoassay kits are standardized using serum-based standards, we hypothesized that measurement of DLIS may be an artifact related to the low protein content of amniotic fluid. We analyzed 12 amniotic fluid samples before and after supplementation with lyophilized human serum. The means +/- SDs for DLIS (nmol/l) at protein concentrations of 0, 32 and 63 g/l were 1.4 +/- 0.16, 0.6 +/- 0.09, and 0.4 +/- 0.09 nmol/l, respectively. We, therefore, hypothesize that DLIS in amniotic fluid may in part be explained by a technical artifact.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.