Abstract

BackgroundConventional quantitative diffusion-weighted imaging (DWI) is sensitive to changes in tissue microstructure, but its application to evaluating patients with orthopaedic hardware has generally been limited due to metallic susceptibility artifacts. The apparent diffusion coefficient (ADC) and T2-values from a multi-spectral imaging (MSI) DWI combined with 2D multi-spectral imaging with a 2D periodically rotated overlapping parallel lines with enhanced reconstruction (2D-MSI PROPELLER DWI) based sequence and a MAVRIC based T2 mapping sequence, respectively, may mitigate the artifact and provide additional quantitative information on synovial reactions in individuals with total hip arthroplasty (THA). The aim of this pilot study is to utilize a 2D-MSI PROPELLER DWI and a MAVRIC-based T2 mapping to evaluate ADC and T2-values of synovial reactions in patients with THA. MethodsCoronal morphologic MRIs from THA patients underwent evaluation of the synovium and were assigned a synovial classification of ‘normal’, or ‘grouped abnormal’ (consisting of sub-groups ‘infection’, ‘polymeric’, ‘metallosis’, ‘adverse local tissue reaction’ [ALTR], or ‘non-specific’) and type of synovial reaction present (fluid-like, solid-like, or mixed). Regions of interest (ROIs) were placed in synovial reactions for measurement of ADC and T2-values, obtained from the 2D-MSI PROPELLER DWI and T2-MAVRIC sequences, respectively. A one-way analysis of variance (ANOVA) and Kruskal-Wallis rank sum tests were used to compare the differences in ADC and T2-values across the different synovial reaction classifications. A Kruskal-Wallis test was used to compare the ROI areas for the ADC and T2-values. A principal component analysis (PCA) was performed to evaluate the possible effects of ADC values, size of the ADC ROI, T2-values, and size of the T2 ROI with respect to synovial reaction classification. ResultsDifferences of ADC and T2 among the individual synovial reactions were not found. A difference of ADC between ‘normal’ and ‘grouped abnormal’ synovial reactions was also not detected even as the ADC area of ‘grouped abnormal’ synovial reactions were significantly larger (p = 0.02). The ‘grouped abnormal’ synovial reactions had significantly shorter T2-values than ‘normal’ synovial reactions (p = 0.02), and that the T2 area of ‘grouped abnormal’ synovial reactions were significantly larger (p = 0.01). A larger ROI area on the T2-maps was observed in the mixed synovial reaction type as compared to the fluid-like reaction type area (p = 0.01). Heterogeneity was noted in calculated ADC and T2 maps. PCA analysis revealed obvious clustering by the ‘normal’ and ‘grouped abnormal’ classifications. Conclusions2D-MSI PROPELLER DWI and MAVRIC-T2 generate quantitative images of periprosthetic tissues within clinically feasible scan times. The combination of derived ADC and T2-values with area of synovial reaction may aid in differentiating normal from abnormal synovial reactions between types of synovial reactions in patients with THA.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.