Abstract

We have studied complement activity, total leukocyte counts, PO2 and acid-base balance during a single hemodialysis with cuprophan membranes in a patient with hereditary angioedema and C3NeF-positive chronic membranoproliferative glomerulonephritis. Before, during and after the dialytic procedure plasma complement activity (total hemolytic complement, classical and alternative pathway activities) was not detectable and no C3-conversion occurred, while profound leukopenia (from 8,500 to 1,800 leukocytes/microliter) and hypoxemia (from 101.8 to 86 mmHg PO2) were found within 20 min from the initiation of hemodialysis. Similar results were obtained by studying the same parameters during two additional hemodialytic procedures. In vitro experiments showed that the patient's C3 could not be converted, either by cuprophan or zymosan, a specific and potent complement activator, even under optimal experimental conditions. Our data demonstrate that complement activation is not the only possible mechanism responsible for early leukopenia (as well as hypoxemia) during dialysis with cuprophan membranes.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.