Abstract

Abstract. A suite of diagnostics is applied to in-situ aircraft measurements and one Chemistry-Climate Model (CCM) data to characterize the vertical structure of the Tropical Tropopause Layer (TTL). The diagnostics are based on vertical tracer profiles and relative vertical tracer gradients, using tropopause-referenced coordinates, and tracer-tracer relationships in the tropical Upper Troposphere/Lower Stratosphere (UT/LS). Observations were obtained during four tropical campaigns performed from 1999 to 2006 with the research aircraft Geophysica and have been compared to the output of the ECHAM5/MESSy CCM. The model vertical resolution in the TTL (~500 m) allows for appropriate comparison with high-resolution aircraft observations and the diagnostics used highlight common TTL features between the model and the observational data. The analysis of the vertical profiles of water vapour, ozone, and nitrous oxide, in both the observations and the model, shows that concentration mixing ratios exhibit a strong gradient change across the tropical tropopause, due to the role of this latter as a transport barrier and that transition between the tropospheric and stratospheric regimes occurs within a finite layer. The use of relative vertical ozone and carbon monoxide gradients, in addition to the vertical profiles, helps to highlight the region where this transition occurs and allows to give an estimate of its thickness. The analysis of the CO-O3 and H2O-O3 scatter plots and of the Probability Distribution Function (PDF) of the H2O-O3 pair completes this picture as it allows to better distinguish tropospheric and stratospheric regimes that can be identified by their different chemical composition. The joint analysis and comparison of observed and modelled data allows to state that the model can represent the background TTL structure and its seasonal variability rather accurately. The model estimate of the thickness of the interface region between tropospheric and stratospheric regimes agrees well with average values inferred from observations. On the other hand, the measurements can be influenced by regional scale variability, local transport processes as well as deep convection, that can not be captured by the model.

Highlights

  • The extreme dryness of the stratosphere was used by Brewer (1949) to deduce that air entered the stratosphere primarily in the tropics, within the so called Tropical Tropopause Layer (TTL) (Highwood and Hoskins, 1998; Folkins et al, 1999; Gettelman and Forster, 2002)

  • The tape recorder is the name given to the slow upward movement of trace gases into the tropical stratosphere and apparently all that is required for a tape recorder is a trace gas that varies in concentration with time near the tropical tropopause

  • What appears from the comparison of the water vapour tape recorder between the Chemistry-Climate Model (CCM) and Halogen Occultation Experiment (HALOE) measurements (Fig. 9b of Eyring et al, 2006) is a phase lag spanning from two to five months in the models, consistent with ECHAM5/Messy phase lag respect to Microwave Limb Sounder (MLS)

Read more

Summary

Introduction

The extreme dryness of the stratosphere was used by Brewer (1949) to deduce that air entered the stratosphere primarily in the tropics, within the so called Tropical Tropopause Layer (TTL) (Highwood and Hoskins, 1998; Folkins et al, 1999; Gettelman and Forster, 2002). The validation of CCMs with observational data sets from in-situ or remote sensing measurements can further be improved using diagnostics that are able to reveal peculiar features in the tropical UT/LS tracers distribution These diagnostics are key indicators of whether the contributions of dynamics and chemistry to the tropical tropopause region are correctly represented in the models, and have been used by several authors to perform comparisons between models and measurements, e.g. in the extra-tropics. The diagnostics used, which have been successfully applied in the extra-tropical tropopause region (Pan et al, 2007; Hegglin et al, 2009), are based on the analysis of vertical profiles of water vapour, ozone, and nitrous oxide and of relative vertical ozone and CO gradients, in a tropopause-referenced coordinate, and on CO-O3 and H2O-O3 correlations They are applied to observational and model data, encouraging in this way a comparison between the model and the observations, with a threefold objective:.

The measurement campaigns
Numerical model
Diagnostic methods
Tropopause coordinates
Vertical tracer gradients
Tracer-tracer correlations
Data handling
Measured versus modelled vertical profiles and relative gradients
Water vapour
Nitrous oxide
Tracer relative vertical gradients in the TTL
Tracer-tracer correlations in the TTL
Findings
Conclusions
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.