Abstract

ContextIn 2015, the updated Prostate Imaging Reporting and Data System version 2 (PI-RADSv2) for the detection of prostate cancer (PCa) was established. Since then, several studies assessing the value of PI-RADSv2 have been published. ObjectiveTo review the diagnostic performance of PI-RADSv2 for the detection of PCa. Evidence acquisitionMEDLINE and EMBASE databases were searched up to December 7, 2016. We included diagnostic accuracy studies that used PI-RADSv2 for PCa detection, using prostatectomy or biopsy as the reference standard. The methodological quality was assessed by two independent reviewers using the Quality Assessment of Diagnostic Accuracy Studies-2 tool. Sensitivity and specificity of all studies were calculated. Results were pooled and plotted in a hierarchical summary receiver operating characteristic plot with further exploration using meta-regression and multiple subgroup analyses. Head-to-head comparison between PI-RADSv1 and PI-RADSv2 was performed for available studies. Evidence synthesisTwenty-one studies (3857 patients) were included. The pooled sensitivity was 0.89 (95% confidence interval [CI] 0.86–0.92) with specificity of 0.73 (95% CI 0.60–0.83) for PCa detection. Proportion of patients with PCa, magnetic field strength, and reference standard were significant factors affecting heterogeneity (p<0.01). Multiple subgroup analyses showed consistent results. In six studies performing head-to-head comparison, PI-RADSv2 demonstrated higher pooled sensitivity of 0.95 (95% CI 0.85–0.98) compared with 0.88 (95% CI 0.80–0.93) for PI-RADSv1 (p=0.04). However, the pooled specificity was not significantly different (0.73 [95% CI 0.47–0.89] vs 0.75 [95% CI 0.36–0.94], respectively; p=0.90). ConclusionsPI-RADSv2 shows good performance for the detection of PCa. PI-RADSv2 has higher pooled sensitivity than PI-RADSv1 without significantly different specificity. Patient summaryWe reviewed all previous studies using Prostate Imaging Reporting and Data System version 2 (PI-RADSv2) for prostate cancer detection. We found that the updated PI-RADSv2 shows significant improvement compared with the original PI-RADSv1.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.