Abstract
Determination of operating characteristics of the test based on blood plasma redox potential monitoring in patients with different patho- logical conditions associated with impaired oxygen metabolism during treatment in postoperative period and expanding the range of parameters of the developed method of investigation of blood plasma redox potential. It were examined healthy volunteers group as following group (n = 63), groups of patients with transplanted liver (n = 64), kidney (n = 59), and lungs (n = 7). Redox potential measurements were done by platinum electrode, reference electrode was silver-chlorine one. Potentiostate IPC-ProL was used to registrate and record a dependence redox potential via time. Time of measurement was 15 min. statistically significant differencees of redox potentials ranges was found in healthy volunteers and patients with transplanted kidney and liver. Ratio of measured redox potentials coincident with the values within the confidence interval in healthy volunteers was 12% in patients with transplanted kidney and 10% in patients with transplanted liver. We observed significant differences in the nature of changes of blood plasma's redox potential values in course of monitoring of subgroups of patients with and without complications after liver transplantation. It was found that sensitivity of electrochemical method was 85%, selectivity--69.8%, precision--85.2%. we discovered value ranges of blood plasma redox potential typicalfor different pathological states; we detected an interaction between the effect of treatment and quantitative changes in the values of the blood plasma redox potentials; criterion for early predicition of complications in patients with transplanted liver was proposed basing on redox potential monitoring during postoperative period.
Highlights
Determination of operating characteristics of the test based on blood plasma redox potential monitoring in patients with different pathological conditions associated with impaired oxygen metabolism during treatment in postoperative period and expanding the range of parameters of the developed method of investigation of blood plasma redox potential
Conclusion: we discovered value ranges of blood plasma redox potential typical for different pathological states; we detected an interaction between the effect of treatment and quantitative changes in the values of the blood plasma redox potentials; criterion for early predicition of complications in patients with transplanted liver was proposed basing on redox potential monitoring during postoperative period
The Lung Transplantation Handbook (Second Edition): A Guide for Patients Paperback
Summary
Результаты: обнаружены статистически достоверные различия в диапазонах величин редокс-потенциала для практически здоровых людей и пациентов с трансплантированными почкой и печенью. Доля измеренных величин редокс-потенциалов, совпадающих с величинами, находящимися в пределах доверительного интервала редокс-потенциалов практически здоровых людей, составила 12% для пациентов с трансплантированной почкой и 10% для пациентов с трансплантированной печенью. Обнаружено существенное различие в характере изменений величин редокс-потенциала плазмы крови при мониторинге подгрупп пациентов с наличием и отсутствием осложнений после трансплантации печени. Что чувствительность электрохимического метода определения величин редокс-потенциала плазмы крови составила 85,7%, специфичность — 69,8%, точность — 85,2%. Заключение: обнаружены диапазоны величин редокс-потенциала плазмы крови, характерные для различных патологических состояний; установлена связь эффекта проводимого лечения с количественными изменениями величин редокс-потенциала плазмы крови пациента; предложен критерий для раннего прогнозирования осложнений у пациентов с трансплантированной печенью на основе мониторинга редокс-потенциала в послеоперационном периоде. (Для цитирования: Сергиенко В.И., Хубутия М.Ш., Евсеев А.К., Пинчук А.В., Новрузбеков М.С., Луцык К.Н., Гольдин М.М.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.