Abstract

This study aims to systematically review the diagnostic accuracy of a digital blood pressure measurement device compared to the gold standard mercury sphygmomanometer in published studies. Searches were conducted in PubMed, Cochrane, EBSCO, EMBASE and Google Scholar host databases using the specific search strategy and filters from 1st January 2000 to 3rd April 2021. We included studies reporting data on the sensitivity or specificity of blood pressure measured by digital devices and mercury sphygmomanometer used as the reference standard. Studies conducted among children, special populations, and specific disease groups were excluded. We considered published manuscripts in the English language only. The risk of bias and applicability concerns were assessed based on the author’s judgment using the QUADAS2 manual measurement evaluation tool. Based on the screening, four studies were included in the final analysis. Sensitivity, specificity, diagnostic odds ratio (DOR), and 95% confidence interval were estimated. The digital blood pressure monitoring has a moderate level of accuracy and the device can correctly distinguish hypertension with a pooled estimate sensitivity of 65.7% and specificity of 95.9%. After removing one study, which had very low sensitivity and very high specificity, the pooled sensitivity estimate was 79%, and the specificity was 91%. The meta-analysis of DOR suggests that the digital blood pressure monitor had moderate accuracy with a mercury sphygmomanometer. This will provide the clinician and patients with accurate information on blood pressure with which diagnostic and treatment decisions could be made.

Highlights

  • This study aims to systematically review the diagnostic accuracy of a digital blood pressure measurement device compared to the gold standard mercury sphygmomanometer in published studies

  • Multiple validation studies have been undertaken to assess the importance of the diagnostic accuracy of mercury-based and digital devices for blood pressure monitoring

  • There is a lack of systematic reviews on the diagnostic accuracy of digital blood pressure measurement devices

Read more

Summary

Introduction

This study aims to systematically review the diagnostic accuracy of a digital blood pressure measurement device compared to the gold standard mercury sphygmomanometer in published studies. We included studies reporting data on the sensitivity or specificity of blood pressure measured by digital devices and mercury sphygmomanometer used as the reference standard. A mercury sphygmomanometer is a standard instrument that is used manually to monitor blood pressure in health care facilities This method is considered the gold standard and has been used in practice for more than a hundred ­years[2]. Multiple validation studies have been undertaken to assess the importance of the diagnostic accuracy of mercury-based and digital devices for blood pressure monitoring. These validation studies need to be considered with caution concerning the quality of evidence and standard of method that they have used. The diagnostic accuracy of a digital blood pressure measurement device compared to the gold standard mercury ­sphygmomanometer[8]

Objectives
Methods
Discussion
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.