This paper describes a technique that allows one to identify the faulty condition (open or short circuit) at a termination of a multiconductor transmission line structure by measuring the induced voltage at the other end. The wavelet theory is used to filter out from the signal the components due to unwanted sources, and to decompose it to obtain the fault's signature. The comparison (or matching) algorithm is substituted by an artificial neural network. Two differently designed neural networks are used to validate the results and the overall procedure is also tested on an experimental set-up.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: IEEE Transactions on Components and Packaging Technologies
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.