Abstract

We describe the operation of a commercial system as modified for preparation of CO2 for the CO2 source. AMS samples are automatically combusted in a CHN analyzer, and stable isotope measurements are made on line. We describe the performance of this equipment, with reference to yield, sample contamination, memory effect, accuracy of isotope measurement, convenience and cost. We discuss the current status of dating using the CO2 source. This is the only source in operation at Oxford, and has been in routine dating since September 1989. We assess the practicalities of operation, including the latest measurements on background, memory, sample-size requirements and operating schedules. We also describe modifications to the sputter beam optics and to the gas handling systems.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.