Abstract
We describe recent developments of the gas electron multiplier (GEM), a thin composite mesh acting as proportional avalanche amplifier in gas counters. In beam tests we have verified the excellent efficiency, time resolution and localization accuracy for a GEM with micro-strip read-out. Efficiency, localization accuracy and operation in strong magnetic fields has been verified; operation at rates above 10/sup 6/ Hz/mm/sup 2/ and lifetimes corresponding to at least 10 mC/cm of collected charge have been demonstrated. Refinements in the manufacturing technology have permitted the realization of large size detectors (27 by 25 cm/sup 2/), to be used in conjunction with microstrip gas chambers. With an improved design, stable gains above two thousand have been reached (GEM2000); larger gains can be obtained increasing the thickness of the foils, cascading two GEMs at some distance or in electrical contact. Further developments of the technology and prospective applications are discussed.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.