Abstract

A simple RP-HPLC method for the determination of Rasagiline Mesylate in bulk and tablet dosage form was developed. Numerous HPLC conditions were tested for determination of rasagiline. The best result was achieved by using Purosphere star RP-18, (150×4.6mm), 5µm column and a mobile phase consisting of Potassium Orthophosphate: Acetonitrile (60:40 v/v) adjusted to pH 7.0(±0.05) with Ammonia solution, a flow rate of 1.5 ml/min with ultraviolet detection at 210nm. The correlation coefficients for calibration curves within the detection range of 5-30µg/ml were 0.9993. The within and between-day precision was determined for both retention time and peak area. The retention time of rasagiline is 6.0 minutes.DOI: http://dx.doi.org/10.3329/icpj.v1i9.11620 International Current Pharmaceutical Journal 2012, 1(9): 285-287

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.