Abstract

In the last decade, microsystems evolved to decisive technology in many technical applications. With increasing requirements on the performance of microsystems, more and more dissimilar materials are used in the same assembly. Correspondingly, suitable joining methods are required to fulfil the requirements on good properties of joints. In this study, a new transient liquid phase (TLP) system Au-Sn-Au was developed for potential medical applications in hybrid microsystems. The high and low melting phases Au and Sn were deposited onto diverse substrates by magnetron-sputter-ion plating. The coated substrates were soldered in a microsoldering station under different conditions. The influence of soldering conditions on the microstructure and properties of the joints was investigated. Results show that the developed solder led to high-quality joints that can be used in microsystems for medical applications.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.