Abstract

X‐ray laminographic image can provide more useful information about the internal state of electronic packaging than x‐ray radiographic image does. Many kinds of laminographic system have been developed for obtaining the cross‐sectional image. Proposes an axial laminographic system, which can be constructed by usual automatic radiographic system without any rotating x‐ray head and detector system. Explains that this method can be implemented to make the usual radiographic x‐ray inspection system equal to the power of a laminographic system.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.