Abstract

It is important to obtain repeatable I–V characteristics in order to evaluate the steady-state performance of a PEFC stack. A performance test method would be useful for this purpose; so, we conducted experiments with several PEFC stacks to collect data. In this study, we set two goals. One was to stabilize the PEFC stack output, and the other was to clarify the operating conditions and to determine the accuracy required to control the parameters that affect the I–V characteristic curve, including stack-operating temperature (coolant outlet temperature), gas operating pressure, gas utilization ratio (gas stoichiometry) and gas dew point. Through experiments, we found a means of obtaining repeatable data with a stack voltage accuracy of ±1%.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.